当前位置:首页 > 过刊浏览->2026年第37卷第5期
加氢装置氯化铵结晶模型预测分析与措施
Model prediction analysis and measures for ammonium chloride crystalliza? tion in the hydrogenation unit of beijing gas group
浏览(4) 下载(0)
- DOI:
- 作者:
- 姜一帆1 ,孙 朋2?
Jiang Yifan1 , Sun Peng2?
- 作者单位:
- (1.辽宁锦城利安德巴赛尔石化有限公司,辽宁 盘锦 124021; 2.北方沥青燃料有限公司,辽宁 盘锦 124021)
(1. Liaoning Jincheng Lianan Debasel Petrochemical Co., Ltd., Panjin, 24021, China; 2. Northern Asphalt Fuel Co., Ltd., Panjin, 124021, China)
- 关键词:
- 氯化铵结晶;模型预测;加氢工艺;因素分析
ammonium chloride crystallization; model prediction; hydrogenation process; factor analysis
- 摘要:
- 加氢工艺是石油炼制与炼化一体化生产的核心工艺,装置长周期稳定运行直接决定企业生产效益。针对某炼化一体化企业加氢改质装置热、冷高压分离器系统压差偏高0.305 MPa,且常规空冷器前置注水调控效果不佳的生产难题,文中依托 Aspen Plus 流程模拟平台,采用 PR-NRTL 物性方法构建高压分离系统精细化模型,系统开展氯化铵结晶规律预测研究。通过热力学分析与结晶临界模型计算,明确了装置氯化铵结晶机理、关键结晶区域及主控影响因素,量化了工艺参数、原料杂质含量对结晶量的影响规律。结果表明:热高分气混氢换热器 E-3102 为氯化铵结晶高发区域,系统压力、换热出口温度、原料氮氯杂质含量及循环氢流量共同决定结晶生成量。结合工艺参数优化与注水技改试验,确定最优注水量为 2 600 kg/h,可满足系统水相液相率≥25% 的设计要求,彻底溶解铵盐结晶、抑制设备堵塞与腐蚀问题。优化改造后装置压差稳定控制在 0.108 MPa,运行工况显著改善。研究可为同类加氢装置铵盐结晶防控、系统平稳运行提供工程参考。Hydrotreating is a core process in petroleum refining and integrated refining-petrochemical production, and the longterm stable operation of hydroprocessing units directly governs plant profitability. This study addresses a practical operational issueencountered in a hydro-upgrading unit at an integrated refining-petrochemical complex: the pressure differential across the hot andcold high-pressure separator system reached an abnormally high value of 0.305 MPa, and conventional water injection upstream ofthe air cooler proved ineffective in mitigating it. A rigorous model of the high-pressure separation system was developed in AspenPlus using the PR-NRTL property method, and the crystallization behavior of ammonium chloride was systematically investigated.Thermodynamic analysis coupled with critical crystallization model calculations elucidated the ammonium chloride crystallizationmechanism, identified the key crystallization-prone zones, and quantified the dominant controlling factors. The influences of pro⁃cess parameters and feed impurity concentrations on the amount of crystalline deposit were quantitatively established. The results in⁃dicate that the hot high-pressure separator gas-recycle hydrogen heat exchanger (E-3102) is the most susceptible location for am⁃monium chloride crystallization, and that the extent of crystallization is jointly determined by system pressure, heat-exchanger out⁃let temperature, feed nitrogen and chlorine impurity levels, and recycle hydrogen flow rate. Process parameter optimization com⁃bined with water-injection retrofitting trials identified an optimal water injection rate of 2 600 kg/h, which satisfies the design crite⁃rion of an aqueous-phase liquid fraction of no less than 25% and thereby completely dissolves ammonium salt deposits while sup⁃pressing equipment fouling and corrosion. Following the optimization and retrofitting, the unit pressure differential was stably main⁃tained at 0.108 MPa, representing a marked improvement in operating conditions. The findings offer an engineering reference for am⁃monium salt crystallization prevention and stable operation of similar hydrotreating units.